122
E1070 Service Manual
3
Using the Menus
3.
Press the
key …
Port 1
or
Port 2
is displayed. Use this item to select which port to use for
printing the report.
4.
Toggle between
Port 1
and
Port
2 using the
TARE
or
UNITS
key. Press the
ENTER
key when the choice you want is displayed…
Display shows
buSY
briefly then returns to
.
5.
Press the
UNITS
key…
Min
is displayed. Use this item to set the minimum sample weight as a
percent of capacity.
6.
Press the
key…
Current value is displayed.
7.
Key in a percentage from 0-100% and press
ENTER
…
Min
is displayed.
8.
Press the
UNITS
key…
SiZE
is displayed. This is the sample size parameter. Use this to set the
sample size for the counting application.
9.
Press the
key…
Current sample size is displayed.
10.
Key in a new sample size. Press
ENTER
to accept…
SiZE
is displayed.
11.
Press the
UNITS
key…
ModE 2
is displayed. Use this to select the sampling mode;
buLK
or
dribbL
.
buLK
In bulk sampling method you place the specified number of
items on the scale all at once (in bulk) and the scale
automatically starts to calculate piece weight when the weight
stabilizes. The count is then displayed.
dribbL
In dribble sampling method you count out the specified
number of items onto the scale and when you are ready, press
the
F1
key and the scale starts to calculate piece weight and
then shows the count.
12.
Toggle between the choices by using the
TARE
or
UNITS
key. Press
ENTER
when your choice is displayed…
ModE 2
is displayed.
13.
Press the
UNITS
key…
CLEAr
is displayed. Use this item to clear all the information stored for
this application.
WARNING - Only do this if you are sure you want the
information permanently removed!
You may want to print out the
report before clearing all the information. See step
Summary of Contents for E1070
Page 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Page 6: ...6 E1070 Service Manual ...
Page 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Page 146: ...146 E1070 Service Manual 8 Network Connections ...
Page 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Page 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Page 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Page 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Page 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Page 162: ...162 E1070 Service Manual ...
Page 163: ......