3.5 Supervisor Menu
ConSt
You set the weights for each ingredient and the batch size is
always the total of these ingredient weights.
GroSS
You set the gross weight at which each ingredient will stop.
The ingredient is complete when the gross weight on the scale
reads the value that was set, regardless of the weight on the
scale when the batch was started.
GroSS
You set the percentage of a total batch for each ingredient and
you can pick a batch size and each ingredient amount will be
calculated automatically.
8.
Press the
key…
Current setting is displayed.
9.
Toggle between the choices by pressing the
TARE
or
UNITS
key. Press the
key when your choice is displayed…
Your choice is selected and
tYPE
is displayed.
10.
Press the
UNITS
key…
PrEAct
is displayed. A preact is the time it takes an ingredient (which is
falling from an auger or other feeder) to reach the scale after the auger
or feeder is shut off. There will always be material in “free-fall” after an
ingredient is shut off and the indicator will automatically calculate this
and update this value.
The first time a batch is run, overage for any ingredient weight is
calculated and the next time the ingredient is being weighed the output
will be shut down so approximately 70% of the overage is reduced. This
occurs each time a batch is run so that the system quickly learns and
produces accurate batches.
Under this item you can turn the preact on or off, or clear a current
preact.
11.
Press the
key to set the preact…
on
or
oFF
is displayed.
12.
Scroll through the choices (
on
,
oFF
,
CLEAR
) with the
TARE
or
UNITS
key.
Press
ENTER
when your choice is displayed…
PrEAct
is displayed.
13.
Press the
UNITS
key…
Ingr X
is displayed. X is the ingredient number. You have up to 8
ingredients for which you can set the following:
bASiS
Set whether the ingredient is based on weight
(
SCALE
), time (
timE
) or pulse counts (
Cntr
).
See Figure
to reference the Supervisor’s menu.
Summary of Contents for E1070
Page 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Page 6: ...6 E1070 Service Manual ...
Page 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Page 146: ...146 E1070 Service Manual 8 Network Connections ...
Page 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Page 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Page 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Page 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Page 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Page 162: ...162 E1070 Service Manual ...
Page 163: ......