140
E1070 Service Manual
6
Remote Display Functionality
6.2.4 Mode 3: Remote weight display with keypad.
Mode 3 sends G<SP>00000<SP>lb<CR><LF> at the display update rate. The remote
indictor will display Gross or Net weight values only. The host indicator will accept key
press commands when a key is pressed on the remote indicator configured to operate
in mode three.
6.2.5 Mode 4: Remote display with keypad and annunciators.
Mode 4 sends G<SP>00000<SP>lb<CR> <LF><AN1><AN2>…<ANn> <CR><LF> at
the display update rate. The remote indicator will display weight and annunciators such
as; motion, center of zero, outputs or annunciators specific to a configured application.
The host indicator will accept key press commands when a key is pressed on the
remote indicator configured to operate in mode three.
UBx
= Under Target Bars
TGx
= The word target has multiple LED’s under it. The x represents which LED to turn
on.
Opx
= Represents the outputs
N,et
= Net LED’s
T,are
= Tare LED’s
Obx
= Over Target Bars
CMx
= Comma’s
Peak/Count
= Count mode if no units, Peak mode if any unit of measure is turned on.
As you can see the annunciator “NET” is broken into two different bits. One for “N”, the
other for “ET”. The host indicator will transmit a “1” or true in both bit positions to
activate the annunciator “NET”.
Example:
Table 1: Host indicator output protocol
G<SP>00000<SP>lb<CR><LF>
Mode 1 and 3 Remote display input string
G<SP>00000<SP>lb<CR><AN1><AN2>…<ANn><CR><LF>
Mode 2 and 4 Remote display input string w/ Annunciators <ANn>
represents the annunciator bytes that are available for the remote, from the
host.
Table 2: Annunciator map bit table
Annunciator
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
AN1
TG0
N/A
N/A
N/A
N/A
N/A
N/A
CM1
AN2
ET
N
ROSS
G
~
->0<-
TG1
CM2
AN3
OP3
OP2
OP1
RINT
P
ARE
T
CM3
AN4
N/A
PT
N/A
N/A
N/A
N/A
N/A
CM4
AN5
Peak/Count
N/A
N/A
Cust
N/A
KG
LB
CM5
AN6
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CM6
AN7
N/A
UB1
UB2
UB3
UB4
UB5
UB6
N/A
AN8
N/A
OB1
OB2
OB3
OB4
OB5
OB6
N/A
Summary of Contents for E1070
Page 1: ...Model E1070 Indicator Service Manual NORTH AMERICA AWT35 500106 Issue AF March 2010 ...
Page 6: ...6 E1070 Service Manual ...
Page 51: ...E1070 Service Manual 51 3 4 Service Menu Table 3 1 Printalbe Characters Chart ...
Page 146: ...146 E1070 Service Manual 8 Network Connections ...
Page 150: ...150 E1070 Service Manual 10 2 Complete Service Menu ...
Page 153: ...E1070 Service Manual 153 11 3 Wall Mount Application ...
Page 154: ...154 E1070 Service Manual 11 4 System Block Diagram ...
Page 155: ...E1070 Service Manual 155 11 5 Keypad Schematic and Power Supply Bd P N 60071 0016 ...
Page 158: ...158 E1070 Service Manual 11 8 I O External Calbe Identification Pin outs ...
Page 162: ...162 E1070 Service Manual ...
Page 163: ......