139
-
Enable/disable the
POS Keyword
check box, to scan the data from the POS if it matches
-
Enable/disable the
Alarm Button
check box, to active manual alarm function. To define
alarm message of manually alarm trigger. Click alarm button and select the alarm button #
and fill in the description of alarm button. When the alarm buttons have been setup, the
Alarm Button icon will show up on the DVR application UI. User can click the Alarm button
icon to trigger the pre-defined alarm.
6. In
(5) Alarm Reset
, click the camera number (01 to 16) to set the reset condition of alarm.
Once alarm is reset, all alarm action will stop at the moment. If the sensor normal status is high,
set the sensor condition to low.
To set sensor status of IP camera, click
IP Camera Sensor
. In IP Camera Alarm Setting
windows, click
High
/
Low
to set sensor status.
-
Alarm Reset Time:
Set a time for the alarm auto reset. When an alarm happen such as
motion detected and video loss, the alarm will reset at the alarm reset time.
7. In
(6) Priority
, set the priority of this alarm set.
8. In
(7) Action
,
you may now set the alarm action for the system to perform when the alarm
condition is activated.
-
Launch EMAP
Display mini EMAP screen.
Summary of Contents for IWH5000 Series
Page 1: ...IWH5000 series IWH5416 16 IWH5416 Touch II User s Manual v 1 1 0 0 ...
Page 54: ...46 9 User can select the Date Camera and Cycle to view the report of object counts In Out ...
Page 65: ...57 3 Select and click one in the bookmark list to preview the file ...
Page 238: ...230 7 Select Add Zone Domians Service to register the domain name ...