DHN Series Network Video Recorder User Manual
118
9.2.6
Configuring Multicast
Purpose:
The multicast can be configured to realize live view for more than 128 connections through network for the device.
A multicast address spans the Class-D IP range of 224.0.0.0 to239.255.255.255. It is recommended to use the IP
address ranging from 239.252.0.0 to 239.255.255.255.
Steps:
1.
Enter the Network Settings interface.
Menu >Configuration> Network
2.
Select the
More Settings
tab to enter the More Settings interface, as shown in Figure 9. 77.
3.
Set
Multicast IP
, as shown in Figure 9. 88. When adding a device to the Network Video Surveillance
Software, the multicast address must be the same as the NVR’s multicast IP.
Figure 9. 8
Configure Multicast
4.
Click the
Apply
button to save and exit the interface.
The multicast function should be supported by the network switch to which the NVR is connected.
9.2.7
Configuring RTSP
Purpose:
The RTSP (Real Time Streaming Protocol) is a network control protocol designed for use in communication
systems to control streaming media servers.
Steps:
1.
Enter the Network Settings menu
Menu >Configuration> Network
2.
Select the
More Settings
tab to enter the More Settings menu, as shown in Figure 9. 77.
Figure 9. 9
RTSP Settings Interface
3.
Enter the RTSP port in the text field of
RTSP Service Port
. The default RTSP port is 554, and you can
change it according to different requirements.
4.
Click the
Apply
button to save and exit the menu.
Summary of Contents for DHN Series
Page 1: ...DHN Series Network Video Recorder User Manual REV 20140423...
Page 99: ...DHN Series Network Video Recorder User Manual 98 Figure 7 35 Synchronizing...
Page 146: ...DHN Series Network Video Recorder User Manual 145 Figure 10 26 View HDD Status 2...
Page 155: ...DHN Series Network Video Recorder User Manual 154 Figure 12 6 HDD Information Interface...