Component replacement
Variable-speed fans
Maintenance Procedures
275
December 2003
8
Component replacement
This chapter describes how to replace components in the system. It includes the following topics:
•
•
Reseating and replacing circuit packs
•
—
Reseating/replacing S8100 circuit packs
—
•
S8300 and G700 component maintenance
—
Replacing the G700 Media Gateway
—
Replacing the S8300 Media Server or hard drive
—
—
Replacing Avaya Expansion Modules
—
Replacing an Avaya Octaplane Stacking Module
•
—
Replacing the S8500 hard drive
—
Replacing the S8500 Media Server
—
Replacing the Remote Supervisor Adapter (RSA)
—
Replacing the S8500 dual network interface
•
—
Replacing the S8700 Media Server
—
Replacing the S8700 hard drive
•
•
Variable-speed fans
A variable-speed fan is identified by the following features:
•
A fan and air filter assembly with product code ED-67077-30, Group 4 or greater, labeled on the
front of the carrier
•
A 5-pin white connector mounted next to each fan on the fan assembly cover plate for speed
control and alarm circuitry
•
A 2-pin black -48 V power connector to each fan
•
A power filter (ED-1E554-30, G1 or G2) located in a metal box mounted behind the fans on the
right-hand cable trough as you face the rear of the cabinet
•
The AHD1 circuit pack and the two S4 sensors used with older fan assemblies are absent.