Additional maintenance procedures
Setting G700 synchronization
410
Maintenance Procedures
December 2003
NOTE:
The following command is issued from the SAT CLI, and not from the MGP CLI.
To test for slippage, from the SAT, issue the command:
test mo logical 4255 physical 1v4 test 144
Table 97: mgp-001-1(configure)# show sync timing
Source
MM
Status
Failure
Primary
Not Configured
Secondary
Not Configured
Local
v0
Active
None
Comment: No failures, SIG GREEN on and ACT on when trunk is seized.
Table 98: mgp-001-1(configure)# set sync interface primary v4
mgp-001-1(configure)# show sync timing
Source
MM
Status
Failure
Primary
V4
Locked Out
None
Secondary
Not Configured
Local
V0
Active
None
Comment: No failures, Sig is green and ACT On 2.8s off 0.2s
Note that the MM710 in slot 4 has been declared to be the primary sync source but it is not active
until the next command is issued.
Table 99: mgp-001-1(configure)# set sync source primary
mgp-001-1(configure)# show sync timing
Source
MM
Status
Failure
Primary
V4
Active
None
Secondary
Not Configured
Local
V0
Standby
None
Comment: The ACT LED does not change its behavior.