Maintenance Procedures
323
December 2003
Removing the fan unit
1
Locate the fan slot adjacent to the power plug on the rear of the server.
2
Remove the two screws holding the fan unit. You do not need to unplug the fan unit.
3
Set the adapter-support bracket to the right of the fan.
Removing the old NIC
1
Completely unscrew the captive screw on the left hand side of the PCI-2 slot.
The captive screw is now loose so that you can flip it up. You will need this space to maneuver the
old NIC out of its slot.
2
Firmly pull the card out of its slot.
Installing the small faceplate on the NIC
One type of NIC comes from the factory with a standard faceplate. You must remove this faceplate and
replace it with a smaller one that fits the space. See
Figure 98, Replacing the faceplate,
If you have a NIC that does not require a small faceplate, proceed to
1
Using a #1 Phillips screwdriver, unscrew the two screws holding the larger faceplate.
2
Remove the faceplate from the NIC.
3
Position the small faceplate over the Ethernet ports. The faceplate must align with the screw holes
on the circuit board.
4
Screw the small faceplate onto the circuit board using the two screws removed in step 1.