Additional maintenance procedures
TN760E tie trunk option settings
388
Maintenance Procedures
December 2003
7
Repeat Steps 13 through 16 of the
TN760E tie trunk option settings
S8100 only
The TN760E Tie Trunk circuit pack interfaces between 4 tie trunks and the TDM bus. Two tip and ring
pairs form a 4-wire analog transmission line. An E and M pair are DC signaling leads used for call setup.
The E-lead receives signals from the tie trunk and the M-lead transmits signals to the tie trunk.
To choose the preferred signaling format (
Table 91, Signaling Formats for TN760E,
Table 92, Signaling type summary,
on page 388), set the switches on the TN760E and administer the port
using
Figure 117, TN760E tie trunk circuit pack (component side) (R758183),
on page 389 and
TN760E option switch settings and administration,
Port 1
(type 5)
(simplex)
Port 2
(type 5)
(simplex)
T1
connected to
T12
R1
connected to
R12
T11
connected to
T2
R11
connected to
R2
Table 91: Signaling Formats for TN760E
Mode
Type
E & M
Type I Standard (unprotected)
E & M
Type I Compatible (unprotected)
Protected
Type I Compatible, Type I Standard
Simplex
Type V
E & M
Type V
E & M
Type V Revised
Table 92: Signaling type summary
Transmit (M-Lead)
Receive (E-Lead)
Signaling type
On-hook
Off-hook
On-hook
Off-hook
Type I Standard
ground
battery
open
1
/battery
ground
(1 of 2)