Additional maintenance procedures
Setting G700 synchronization
Maintenance Procedures
411
December 2003
The results from the above command are shown in
If a secondary is similarly provisioned:
To activate the secondary, the following is similarly done:
To activate local the following is done:
Table 100: TEST RESULTS
Port
Maintenance
Name
Alt. Name
Test No.
Result
Error Code
001V4 MG-DS1
144
PASS
Command successfully completed
Table 101: mgp-001-1(configure)# set sync interface secondary v3
mgp-001-1(configure)# show sync timing
SOURCE
MM
STATUS
FAILURE
Primary
V4
Active
None
Secondary
V3
Standby
None
Local
V0
Standby
None
Table 102: mgp-001-1(configure)# set sync source secondary
mgp-001-1(configure)# show sync timing
Source
MM
Status
Failure
Primary
V4
Locked Out
None
Secondary
V3
Active
None
Local
V0
Standby
None
Note: The system uses one clock at a time only: therefore only the secondary is active and the
primary is locked out.
Table 103: mgp-001-1(configure)# set sync source local
mgp-001-1(configure)# show sync timing
Source
MM
Status
Failure
Primary
V4
Locked Out
None
Secondary
V3
Locked Out
None
Local
V0
Active
None