6-2
OVERVIEW: DEFINITY GENERIC 2 WITH UNIVERSAL MODULES
CC Carrier (J58888AB)
The CC carrier fulfills the same function for DEFINITY Generic 2 with universal modules that it does
in System 85 and DEFINITY Generic 2 with traditional modules.
TMS Carrier (J58888C)
The TMS performs the same function in DEFINITY Generic 2 with universal modules that it does in
System 85 and DEFINITY Generic 2 with traditional modules. In DEFINITY Generic 2 with universal
modules, the ODL®-50 fiber-optic paddleboards replace the ODL®-40 series, allowing remote modules
to be connected up to 25,000 ft away.
CPC (J58890BB)
The CPC (J58890BB) for the DEFINITY Generic 2 universal module is not compatible with System 85
or DEFINITY Generic 2 with traditional modules. The CPC is capable of supporting 20 ports per
carrier. It fulfills the same functions in DEFINITY Generic 2 with universal modules that the DS1 and
port carriers do in System 85 and DEFINITY Generic 2 with traditional modules.
The CPC introduces a major improvement in cabling between the switch and wall fields with the new
I/O connector plate on the rear of the UMC cabinet. The I/O connector plate provides 20 25-pair
connectors to interface circuit pack slots to the cross-connect field. The cables for these connections are
B25A male-to-female (M-F) connectors, replacing the male-to-male (M-M) versions used in other
System 85 connectorized systems. M-M A25D cables are available to connect switches to wall fields
already installed with female connectors.
UMC Carrier (J58890AK-1)
The UMC carrier fulfills the same function in DEFINITY Generic 2 with universal modules that the MC
carrier (J58888M) does in System 85 and DEFINITY Generic 2 with traditional modules.
The UMC has an I/O connector accessible from the rear of the cabinet to provide an interface with
cross-connect fields, remote modules, and internal connections to other carriers and hardware devices.
The UMC has 23 slots: 2 for power, and 21 for circuit packs.
Remote Groups
Remote groups are not supported by DEFINITY Generic 2 with universal modules.
Summary of Contents for 9601
Page 1: ...555 104 630 Issue 2 June 1991 DEFINITY Communications SystemGeneric 2 and System 85 Wiring ...
Page 57: ...2 34 MDF IDF DESIGN SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 67: ...3 10 ELECTRICAL PROTECTION SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 73: ...4 6 PORT PACKS DCP REPEATERS SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 85: ...6 6 OVERVIEW DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 119: ...7 34 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 123: ...8 4 ELECTRICAL PROTECTION DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 135: ...10 8 INSTALLATION EXAMPLE DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 139: ...11 4 BRI DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 174: ...GL 12 GLOSSARY ...