PORT PACKS/DCP REPEATERS: SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES
TABLE 4-3. Voice Terminal Loop Ranges
Voice Terminal
Distance (Ft)
Comments
24AWG
26AWG
Analog
All sets
5380
3500
Using SN229 circuit pack
2500 series
18,460
12,000
Using SN228 or SN228B circuit pack
7100 series
13850
9000
Using SN228 or SN228B circuit pack
Hybrid
7203H
3540
2300
7205H
3540
2300
1690
1100
With 1 module
1150
750
With 2 modules
7303S
1540
1000
1000
650
With 1 adjunct
3075
2000
With adjunct power supplied from
the closet or at the workstation
7305S
1000
650
690
450
With 1 adjunct
3075
2000
With adjunct power supplied from
the closet or at the workstation
Digital
740X
5230
3400
With adjunct power supplied from
the closet or at the workstation.
Loop range can be extended 5000
ft with each DCP repeater. A
maximum of 6 DCP repeaters can
be linked together.
7695
5000
Loop range can be extended 5000
ft with each DCP repeater. A
maximum of 6 DCP repeaters can
be linked together.
Summary of Contents for 9601
Page 1: ...555 104 630 Issue 2 June 1991 DEFINITY Communications SystemGeneric 2 and System 85 Wiring ...
Page 57: ...2 34 MDF IDF DESIGN SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 67: ...3 10 ELECTRICAL PROTECTION SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 73: ...4 6 PORT PACKS DCP REPEATERS SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 85: ...6 6 OVERVIEW DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 119: ...7 34 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 123: ...8 4 ELECTRICAL PROTECTION DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 135: ...10 8 INSTALLATION EXAMPLE DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 139: ...11 4 BRI DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 174: ...GL 12 GLOSSARY ...