9-4
PORT PACKS: DEFINITY GENERIC 2 WITH UNIVERSAL MODULES
TABLE 9-3 Voice Terminal Loop Ranges
Distance (Ft)
Terminal Type
Comments
24 AWG
26 AWG
Analog
500/2500
20000
13000
On-premises or out-of-building —
same premises (TN742, TN769).
500/2500
3100
2000
On-premises only — no bridging
terminals without adjuncts
(TN742).
710X
15200
10000
Hybrid
730X
1000
750
Without adjunct power
2000
2000
With adjunct power
Digital
740X
3000
2200
On premises
2400
1300
Out-of-building same premises
B R I
750X
1900
1600
Adjunct Power required on all
terminals
All 750X terminals require a
terminating resistor. These figures
assume the resistor is installed
within 33’ (IOM) of the terminals.
DCP REPEATERS
Basic guidelines for DCP repeaters are the same for DEFINITY Generic 2 with universal modules as
they are for System 85 and DEFINITY Generic 2 with traditional modules. See chapter 4,
Portpacks/DCP Repeaters: System 85 and DEFINITY Generic 2 with Traditional Modules for more
detailed information.
Summary of Contents for 9601
Page 1: ...555 104 630 Issue 2 June 1991 DEFINITY Communications SystemGeneric 2 and System 85 Wiring ...
Page 57: ...2 34 MDF IDF DESIGN SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 67: ...3 10 ELECTRICAL PROTECTION SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 73: ...4 6 PORT PACKS DCP REPEATERS SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES ...
Page 85: ...6 6 OVERVIEW DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 119: ...7 34 MDF lDF DESIGN DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 123: ...8 4 ELECTRICAL PROTECTION DEFINlTY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 135: ...10 8 INSTALLATION EXAMPLE DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 139: ...11 4 BRI DEFINITY GENERIC 2 WITH UNIVERSAL MODULES ...
Page 174: ...GL 12 GLOSSARY ...