Owner Installation Instructions
GDO-10V2L2 Toro
™
45
Symptom
Possible cause
Remedy
Door will not operate
Mains power not switched on.
Door is obstructed.
Door is locked or motor jammed.
Door tracks/hardware damaged.
The stop function is activated
The opener is in “Vacation Mode”
Switch on mains power.
Remove obstruction.
Unlock door or remove jam.
Door requires service/repair by
qualifi ed technician.
Deactivate the stop switch/timer
Turn off “Vacation Mode”.
Door starts to close but
automatically reverses to open
position
Adverse weather conditions (wind
or cold) causing door to stiffen and
become tight in the tracks.
Possible obstruction in the
doorway.
Increase force margin setting
refer to page 19 or re-calculate
force margin.
Remove obstruction.
Door operates from wall control
unit (OPEN/CLOSE) button but not
from transmitter
Transmitter code not stored in
memory.
Code transmitter in to openers
memory.
Flat battery
Replace battery
Door does not close with
transmitter
Safety Close Mode is on.
Safety Beam not installed or not
working properly.
Turn the Safety Close Mode off
Make sure Safety Beam are
operational.
Door will not close fully.
Door limits positions need to be
reset.
Reset limits positions.
Door will not open fully.
Door limits positions need to be
reset.
Reset limits positions.
Auto-Close not working
Safety Beam not installed.
Install Safety Beam.
Safety Beam or wiring faulty.
Repair Safety Beam or replace
wiring.
Safety Beam not aligned correctly.
Re-align optics.
Safety Beam is obstructed.
Remove obstruction from path of
Safety Beams.
Door obstructed when closing.
Remove obstruction.
Auto-Close time not set.
Set Auto-Close times.
Auto-Close mode not set
Set Auto-Close mode.
Troubleshooting