Service Counter
(Cycles) 60000
1: Open Cycles
(Cycles) 500
61
fi g
60
fi g
Menu 8.5 Service Counter
The opener provides a periodic service counter which
can be set to expire after a number of drive cycles.
When expired, the opener will beep three times at
the beginning of each drive cycle and a message will
be displayed on the MAIN SCREEN
(Fig. 60).
This
tool displays the current value of the service counter
and allows the user to set its value using the normal
parameter editing techniques (See PARAMETER
VIEWING AND EDITING). If the service counter is not
to be used, it can be set to the maximum number
(60,000).
Menu 8.6 Event Counters
The opener keeps a count of number of times a
particular event occurs. The list of event counters
kept is shown below. When this tool is selected, the
fi rst event counter is shown
(Fig. 61).
Press NEXT or
PREV to step through the list. The example shows the
OPEN CYCLE event counter with a value of 500. When
fi nished viewing press STOP.
1: Open Cycles 2: Close Cycles
3: PED Cycles 4:Warranty Cycles
5: Open Obstructions 6: Close Obstructions
7: Open O/LS 8: Close O/LS
9: Setup Limits 10: Drive Faults
11: Volt Faults 12: Low Motor Amp Faults
13: Amp ADC Faults 14: Supply Hi Faults
15: Supply Low Faults 16: Amp Trip Faults
17: Position Sensor faults 18: Drive Memory Faults
19: Position Wrap Faults 20: Direction Faults
Menu 8.7 Install Data
Open Position
Shows the fully open position door counter.
PED Position
Shows the pedestrian position counter.
Open Time
Time taken for the opener to drive the door to open
position.
Close Time
Time taken for the opener to drive the door to the
close position.
Diagnostic Tools
Menu 8.8 Parameters
Supply voltage, cutout maximum current allowed
to use by the opener, percentage of charge in
the batteries, battery voltage, battery charging
voltage, motor voltage, current used by the
system and current position counter value are
displayed under this menu.
All the parameters mentioned above can also be
viewed while the opener is running. By default,
the current used by the motor will be displayed
on the LCD screen. This can be useful to check
the condition of the door. Scroll through other
parameters by pressing NEXT or PREV buttons
while the door is running
Menu 8.9 Version Info
Firmware information for the GDO10V2L2 drive
and console are shown here.