38
GDO-10V2L2 Toro
™
Owner Installation Instructions
Accessories Installation
Memory Tools
62
fi g
LIGHT
LOCK
LIGHT
NO
NC
COM
NO
NC
COM
SUITABLE
POWER
SUPPLY
Parameter
Min
Max
Default
Step
Unit
Menu No.
ON AFTER CYCLE LIGHT TIME
Time light remains on for after a cycle
0
255
60
1
Sec
4.1
ON BEFORE OPEN CYCLE LIGHT TIME
Minimum time light is activated for prior to
opening
0
25.5
0
0.1
Sec
4.2
ON BEFORE CLOSE CYCLE LIGHT TIME
Minimum time light is activated for prior to
closing
0
25.5
0
0.1
Sec
4.3
Step 15 - Courtesy Lights
Step 15.1 - Fitting Courtesy Lights
An AC or DC courtesy light can be activated via an
output on the door opener control board. Connect the
light as per the diagram.
(Fig. 62)
WARNING: A qualifi ed electrician must perform
the installation where 240V AC power is used.
Menu 4. Light/Lock Times
Press NEXT or PREV on the wall control unit to
navigate to Menu 5 Light/Lock Times.
Press SET to select the sub menu.
Press NEXT or PREV to navigate through the sub
menu.
Press OPEN to increase or CLOSE to decrease the
time.
Press SET to save the new time.
Press the STOP button two times to exit.
Test the light operation.
1.
2.
3.
4.
5.
6.
7.
Menu 9.0 Memory Tools
The Memory Tools accessed from within Menu 9 are used to clear the transmitters codes from the openers
memory and clear the controller’s memory. Once selected, the PREV or NEXT buttons can be used to view the
Memory Tool options. To execute the displayed option, simply press SET.
Menu 9.1 Clear Control
This option will clear the door control memory and reload the factory set defaults for parameters such as the
lock time, light time, Auto-Close times etc. It will also clear the travel limits.
Menu 9.2 Clear Tx’ers
This option will clear the transmitter storage memory.