Owner Installation Instructions
GDO-10V2L2 Toro
™
17
Setting Limits
14
fi g
To Desired
CLOSE Limit,
SET
To Desired
OPEN Limit,
SET
16
fi g
Step 6.1 - Setting Travel Limits
WARNING! Use caution when operating the
manual release with the door open since it may
fall rapidly due to weak or broken springs, or
an improperly balanced door.
CAUTION! Do not disengage the opener to
manual operation with children, persons or
any objects including motor vehicles within the
doorway.
Secure the engage/disengage handle and string
with the accessory supplied in such a manner so
that the string is away from the moving parts.
Move the door to half way open. If necessary,
disengage the opener by pulling the cord down
(Fig.14)
. Re-engage the opener by pulling the cord
down again.
Turn on the power to the opener.
The controller will
go through a start up sequence.
After a short delay the MAIN SCREEN
(Fig. 15)
will be displayed. If this is the fi rst time the GDO-
10v2L2 is being used, the MAIN SCREEN should
enter into limit set mode and the blue close LED
will be fl ashing. If the display shows that an input is
active, then rectify the situation before continuing
with the procedure for setting the travel limits.
Press and hold the CLOSE button - the door should
start closing.
If the door opens, release the CLOSE
button and press the STOP button once
to change the motor’s direction. Press and
hold the CLOSE button until close position
of the door is reached.
If the door overshoots press the OPEN
button to move the door in the open
direction.
When the door is at the desired close position, press
the SET button to record the close limit position. The
display will change and green open LED will start to
fl ash
(Fig. 16)
.
Press and hold the OPEN button to open the door.
When the door is at the desired open position, release
the OPEN button
If the door overshoots, press the CLOSE
button to move the door in the CLOSE
direction.
WARNING!
Once the next step is performed, the
door will automatically close and open to calculate
force settings. Keep persons and objects clear of the
door.
Press the SET button to store the open limit. The door
will now automatically close and open to calculate the
safety obstruction settings. After this, if Safety Beam
is installed, the opener can be operated with the
OPEN or CLOSE button on the wall control unit or
from the transmitter. Otherwise, the controller will be
loaded with “Safety Close Mode.” See Control Board
Adjustments (Page 29) for further details.
a.
b.
c.
d.
»
»
e.
f.
»
g.
15
fi g
Pull Down To
Engage/Disengage