40
GDO-10V2L2 Toro
™
Owner Installation Instructions
Step 17 - Setting Up Auto-Close Mode
NOTE: the Auto-Close function is not available unless Safety Beam is installed.
Auto-Close mode is a function that automatically closes the door a preset time after the Safety Beam recognise
that a vehicle has left the garage.
The Auto-Close timer only starts after the Safety Beam path is broken and the Auto-Close timer has been set.
If the Safety Beam path is not broken, the door will remain open until the path is broken. If the opener incurs
a physical obstruction (i.e. not from the Safety Beam) while closing, the door will re-open and not Auto-Close
until the Safety Beam path is broken again.
Menu 3. Auto-Close Times
The Auto-Close modes automatically close the door after it has been operated. To implement this, the
controller starts a timer once the door has reached its desired open position. The timer then counts down and
when it expires the controller starts to close the door. Details of the four Auto-Close modes are outlined below:
Standard Auto-Close
This mode is selected by entering a non-zero time for the
STD Auto-Close
parameter. When selected, the
door will Auto-Close after being fully opened (except when the door has reversed to the open position after
a motor obstruction or overload unless A/C after open and/or close Obstruction are selected). Countdown is
suspended by: S.B., OPN or SWP input being active. The countdown is aborted if the STP input is activated. If
the door is already open and the OPN or the SWP input is activated, then the countdown will start.
Safety Beam Triggered Auto-Close
This mode is selected by entering a non-zero time for the “
Safety Beam Auto-Close
” parameter. This mode is
used to Auto-Close the door but only after a vehicle have passed through the doorway and has triggered the
Safety Beam input. The swipe input can be used to clear the Safety Beam triggered status so that the Safety
Beam input must be activated again before the countdown will start. As with the other Safety Beam modes,
the STP input will abort countdown and the OPN and SWP inputs will restart the countdown if the door is
OPEN.
Pedestrian Access Auto-Close
This mode is selected by entering a non-zero time for the “
Ped’n A/C
” parameter. When selected, the door will
Auto-Close after being opened for pedestrian access unless it was following a reverse from an obstruction.
Safety Beam triggered pedestrian Auto-Close
This mode is selected by entering a non-zero time for the “
S.B. Ped’n A/C
” parameter. This mode is the
same as the Safety Beam triggered Auto-Close mode but it only operates during pedestrian access. As
the SWP input is not available during pedestrian access, the PED input can be confi gured to act in a SWP
mode by setting the “
PED I/P = PED SWIPE MODE
” parameter to
ON
.
Auto-Close After Obstruction
Three parameters are provided to enable the Auto-Close feature to be activated after obstructions and power
up. Normally the Auto-Close feature is not enabled after obstructions for safety reasons. Safety Beams must be
used for these features to be activated.
Auto-Close Mode