Owner Installation Instructions
GDO-10V2L2 Toro
™
41
Parameter
Min
Max
Default
Step
Unit
Menu No.
STD AUTO-CLOSE TIME
Sets and enables the standard Auto-Close time
0.0
60.0
0.0
1.0
Sec
3
S.B AUTO-CLOSE TIME Sets and enables the S.B
triggered Auto-Close time
0.0
60.0
0.0
1.0
Sec
3
PEDESTRIAN AUTO-CLOSE TIME Sets and
enables the Pedestrian Auto-Close time
0.0
60.0
0.0
1.0
Sec
3
S.B PEDESTRIAN AUTO-CLOSE TIME Sets and
enables the PE Pedestrian Auto-Close time
0.0
60.0
0.0
1.0
Sec
3
AUTO-CLOSE AFTER CLOSE OBSTRUCTION
Enables Auto-Close feature after close
obstructions
Off
On
Off
3
AUTO-CLOSE AFTER OPEN OBSTRUCTION
Enables Auto-Close feature after open
obstructions
Off
On
Off
3
AUTO-CLOSE AFTER POWER UP
Enables Auto-Close feature power up
Off
On
Off
3
Safety Beam Triggered, Directional Auto-Close
This mode is selected by entering a non-zero time for the “
S.B. Auto-Close
” parameter. S.B 3 Beam must be
installed and confi gured to EXIT WITH SB1. Sub in menu 6.5.
This mode is used to Auto-Close the door only after a vehicle has passed through the Safety Beam 3 and then
through Safety Beam 1 to exit the premises .
This mode is useful for fi re brigade, ambulance stations etc.
Step 18 - Installing The Wall Mounted
Transmitter (Optional)
Remove the face plate from the transmitter.
Affi x the base plate at a height of 1.5 metres within
sight of the door. Make sure that the position of
the transmitter is out of reach of children and
convenient to the customer
(Fig. 64).
Replace the face plate.
To code the transmitter, refer to page 21.
a.
b.
c.
d.
64
fi g
Wall Transmitter Installation