System Specifications
Factory Default Settings
Default
Step
Maximum
Maximum motor run time
30 Secs.
-
-
Courtesy light time
3 Mins. approx.
-
-
Obstruction force margin
2
1
14
Auto close time
30 Secs
-
-
Technical Specifications
Input Voltage
120Vac / 60Hz
Fuse (primary)
1.3A (slow blow)
Input power (max)
200 Watts
Standby power, less than
2 Watts
Transformer secondary output Voltage
24Vac
Motor type
24Vdc geared motor with permanent magnet
Shuttle travel distance in the C-Rail
9.19ft (2.8m) approximately (standard)
Maximum shuttle travel distance in the C-Rail
16.4ft (5m) (with extended C-Rail)
Maximum door area
177sq.ft (16.5 m
2
)
Maximum door hanging weight
441lbs (200kg)
Receiver type
UHF Multifrequency FM-Receiver
Receiver code storage capacity
14 X 4 button transmitter codes
Transmitter frequency
433.47MHz; 433.92MHz; 434.37MHz
Coding type
TrioCode™
Number of code combinations
Over 4.29 billion random codes
Code generation
Nonlinear encryption algorithm
Remote control battery
CR2032 3 Volts
Courtesy light
2 LED Modules
Controller fuse
10A (slow blow)
NoTE:
Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra
pressure on the door and tracks which may in turn trigger the safety obstruction detection system intermittently.
PA1000
Instruction Manual (Instructions d’installation)
6