background image

I NSTALLATION  

 

DEFAULT 

STEP 

MAXIMUM 

MAXIMUM MOTOR RUN TIME 

30 Sec. 

COURTESY LIGHT TIME 

3 Min. 

10 Sec. 

10 Min. 

OBSTRUCTION FORCE MARGIN 

10 

20 

AUTO CLOSE TIME 

0 Sec = Off 

5 Sec. 

4 Min. 

FACTORY SET DEFAULTS.

 

DOOR STATUS INDICATORS.

 

  

17 

   DOOR OPENER STATE 

OPEN 

LED 

GREEN 

CLOSE 

LED 
RED 

DOOR 

STATUS 

LED 

 YELLOW 

COURTESY 

LIGHT 

BEEPER 

OPEN 

ON 

  

 

 

 

CLOSE 

 

ON 

 

 

 

OPENING 

FLASHING 

 

 

 

 

CLOSING 

 

FLASHING 

 

 

 

DOOR TRAVEL STOPPED 

FLASHING 

FLASHING 

 

 

 

DOOR OBSTRUCTED WHEN OPENING 

FLASHING 

 

  

 

BEEPS ON AND OFF 

DOOR OBSTRUCTED WHEN CLOSING 

 

FLASHING 

  

 

BEEPS ON AND OFF 

DOOR OVERLOADED 

 

 

  

 FLASHES 

10 TIMES 

BEEPS ON AND OFF 

DOOR  AND OPENER APPROACHING OVER-
LOAD 

 

 

 

 

BEEPS FOR DURATION 

OF  TIME APPROACHING 

OVERLOAD  

DOOR  HAS APPROACHED THE OVERLOAD 
THREE TIMES IN EIGHT CYCLES.  

 

 

ON 

 

BEEPS ONCE AT START 

OF ANY CYCLE 

DOOR IN OPEN POSITION WITH AUTO CLOSE 
MODE SELECTED 

ONE SECOND 

FLASHES 

 

 

 

  

MAINS POWER INTERRUPTED TO OPENER 

RAPID 

FLASHES 

 

 

 

 

Summary of Contents for ROLL UP GARAGE DOOR OPENER

Page 1: ...DOOR OPENER OWNERS COPY Installation Instructions And Owners Manual Warning Failure to comply with the Installation instructions and the Safety warnings may result in Serious Personal injury and or Pr...

Page 2: ...result from failure to follow this warning Make sure that the SAFETY OBSTRUCTION FORCE is working correctly and is TESTED and set as per the Installation Instructions Manual Failure to follow the Man...

Page 3: ...table It is compulsory to in stall a Photo Electric Beam if this mode is selected otherwise the door will not operate SAFETY AUTO RUN TIME If the Opener does not complete its cycle within thirty secon...

Page 4: ...onnected to the Opener by wire cable The monitor indicates the status of the door for example if the door is moving or is opened or closed etc The door can also be controlled from the monitor unit 18...

Page 5: ...DJUST SCREW GREEN 13 CLOSE LIMIT ADJUST SCREW RED 14 OPEN LIMIT CAM GREEN 15 CLOSE LIMIT CAM RED OPERATING CONTROLS 5 1 FORCE MARGIN SET BUTTON 2 OPEN LIMIT LED GREEN 3 OPEN DRIVE BUTTON GREEN 4 O S C...

Page 6: ...KEY RING TRANSMITTER PTX 4 2 3 1 ALKALINE BATTERY A23 12V 2 4 WEIGHT BARS NOT INCLUDED IN SOME COUNTRIES 2 5 WEIGHT BARS ACCESSORY PACK NOT INCLUDED IN SOME COUNTRIES 1 5 1 PAN HEAD SCREW M5x40 4 5 2...

Page 7: ...The door must be well balanced and be in an reasonable oper ating condition You should be able to lift the door smoothly and with little resistance It should stay open around 900mm to 1200mm above the...

Page 8: ...t diffuser and fix the top screw not supplied through the control box see Fig 3 Replace the light dif fuser 4 LEFT OR RIGHT HAND INSTALLATION The Automatic Opener can be installed on the left or right...

Page 9: ...Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is supported remove the right hand door mounting bracket from wall 6 Rem...

Page 10: ...ockwise direction the green limit cam Fig 11 until the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate by hand in a clockwise direction the red li...

Page 11: ...equal to approximately 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30 mm then it is recommended that the red limits cam be adjusted again before the...

Page 12: ...en 30 mm it is recommended that the green limits cam be adjusted again before the green fine adjustment screw is adjusted CLOSE LIMIT ADJUSTMENT Press in and hold the Red Close button Fig 15 The door...

Page 13: ...ressure you can change it as below 8 2 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button 1 Fig 16 2 While holding down button 1 press the green Open button 3 The green LED will i...

Page 14: ...ING THE TRANSMITTERS CODE 1 Press and hold the blue Door Code button on the Control Panel button 9 FIG 18 2 Press the button one of four on the Transmitter you would like to use to control the door fo...

Page 15: ...uld not respond 11 2 DELETING ALL STORED TRANSMITTER CODES 1 Turn the Power Off to the Drive Unit 2 Press and hold the blue Door Code button 9 Fig 21 on the Control panel 3 Turn the Power On again whi...

Page 16: ...o close time has been set If the P E path is not broken the door will remain open till the path is broken If the Door Opener in curs an obstruction not from the P E while closing the door will re open...

Page 17: ...OPENING FLASHING CLOSING FLASHING DOOR TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS ON AND OFF DOOR OBSTRUCTED WHEN CLOSING FLASHING BEEPS ON AND OFF DOOR OVERLOADED F...

Page 18: ...18 SPARE PARTS WHEN ORDERING SPARE PARTS QUOTE THE ORDER CODE NUM BER TO YOUR LOCAL IN...

Page 19: ...ion step 7 and 8 Lights malfunction or keep blowing Globe blown or incorrect globe Replace with 24V DC 15 watts Festoon globe Courtesy Light Flashing The Door Opener has detected a overload condition...

Page 20: ...ich arise out of a accidental damage to or normal wear and tear to the Product or to the Product s components b flood fire or lighting c incorrect improper or unreasonable maintenance and or use d ins...

Reviews: