I NSTALLATION
OPEN LIMIT ADJUSTMENT
Press in and hold the Green Open Button (Fig 14) The
door should start opening. Release the Green Open but-
ton when the door reaches the desired open limit stop
position. If the Green LED (Fig. 14) is illuminated
and the desired limit stop position has been
reached then the limit adjustment is complete. If
the Green LED is illuminated but you are not happy
with the door open position, the Green Fine Adjustment
Screw (Fig. 14) can be adjusted to fine tune
the open position. To open the door more, turn the
Green Fine Adjustment Screw clockwise. To open the
door less turn the Green Fine Adjustment screw
anticlockwise. Each complete revolution of the
adjustment screw is equal to approximately 10 mm
of door travel.
NOTE
: If the door has not reached the desired
limit position by more then 30 mm, it is recommended
that the green limits cam be adjusted again before
the green fine adjustment screw is adjusted.
CLOSE LIMIT ADJUSTMENT
Press in and hold the Red Close button (Fig 15) The
door should start closing. Release the Red Close button
when the door reaches the desired closed limit stop
position. If the Red LED (Fig. 15) is illuminated and
the desired limit position has been reached
then the limit adjustment is complete. If the Red LED
is illuminated but you are not happy with the door
close position, the Red Fine Adjustment Screw (Fig. 15)
can be adjusted to fine tune the close position.
Adjust the screw clockwise to close the door less. To
close the door more adjust the screw anticlockwise.
Each complete revolution of the adjustment screw is
equal to approximately 10 mm of door travel.
NOTE
: If the door has not reached the desired
limit position by more then 30 mm, then it is
recommended that the red limits cam be
adjusted again before the red fine adjustment
screw is adjusted.
12
FIG. 14
FIG. 15