background image

8) 

CLOSE DRIVE BUTTON (RED) 

9) 

DOOR CODE BUTTON (BLUE) 

10)  LIGHT CODE BUTTON  
11)  ENGAGE / DISENGAGE HANDLE 
12)  OPEN LIMIT ADJUST SCREW (GREEN)  
13)  CLOSE LIMIT ADJUST SCREW (RED) 
14)  OPEN LIMIT CAM (GREEN) 
15)  CLOSE LIMIT CAM (RED) 

OPERATI NG CONTROLS   

1) 

FORCE MARGIN SET BUTTON 

2) 

OPEN LIMIT LED (GREEN)  

3) 

OPEN DRIVE BUTTON (GREEN) 

4) 

O/S/C BUTTON (YELLOW) 

5) 

RESET BUTTON  

6) 

AUTO CLOSE TIME BUTTON 

7) 

CLOSE LIMIT LED (RED) 

14

13

12

11

15

4

5

3

1

2

9

10

8

6

7

Summary of Contents for ROLL UP GARAGE DOOR OPENER

Page 1: ...DOOR OPENER OWNERS COPY Installation Instructions And Owners Manual Warning Failure to comply with the Installation instructions and the Safety warnings may result in Serious Personal injury and or Pr...

Page 2: ...result from failure to follow this warning Make sure that the SAFETY OBSTRUCTION FORCE is working correctly and is TESTED and set as per the Installation Instructions Manual Failure to follow the Man...

Page 3: ...table It is compulsory to in stall a Photo Electric Beam if this mode is selected otherwise the door will not operate SAFETY AUTO RUN TIME If the Opener does not complete its cycle within thirty secon...

Page 4: ...onnected to the Opener by wire cable The monitor indicates the status of the door for example if the door is moving or is opened or closed etc The door can also be controlled from the monitor unit 18...

Page 5: ...DJUST SCREW GREEN 13 CLOSE LIMIT ADJUST SCREW RED 14 OPEN LIMIT CAM GREEN 15 CLOSE LIMIT CAM RED OPERATING CONTROLS 5 1 FORCE MARGIN SET BUTTON 2 OPEN LIMIT LED GREEN 3 OPEN DRIVE BUTTON GREEN 4 O S C...

Page 6: ...KEY RING TRANSMITTER PTX 4 2 3 1 ALKALINE BATTERY A23 12V 2 4 WEIGHT BARS NOT INCLUDED IN SOME COUNTRIES 2 5 WEIGHT BARS ACCESSORY PACK NOT INCLUDED IN SOME COUNTRIES 1 5 1 PAN HEAD SCREW M5x40 4 5 2...

Page 7: ...The door must be well balanced and be in an reasonable oper ating condition You should be able to lift the door smoothly and with little resistance It should stay open around 900mm to 1200mm above the...

Page 8: ...t diffuser and fix the top screw not supplied through the control box see Fig 3 Replace the light dif fuser 4 LEFT OR RIGHT HAND INSTALLATION The Automatic Opener can be installed on the left or right...

Page 9: ...Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is supported remove the right hand door mounting bracket from wall 6 Rem...

Page 10: ...ockwise direction the green limit cam Fig 11 until the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate by hand in a clockwise direction the red li...

Page 11: ...equal to approximately 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30 mm then it is recommended that the red limits cam be adjusted again before the...

Page 12: ...en 30 mm it is recommended that the green limits cam be adjusted again before the green fine adjustment screw is adjusted CLOSE LIMIT ADJUSTMENT Press in and hold the Red Close button Fig 15 The door...

Page 13: ...ressure you can change it as below 8 2 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button 1 Fig 16 2 While holding down button 1 press the green Open button 3 The green LED will i...

Page 14: ...ING THE TRANSMITTERS CODE 1 Press and hold the blue Door Code button on the Control Panel button 9 FIG 18 2 Press the button one of four on the Transmitter you would like to use to control the door fo...

Page 15: ...uld not respond 11 2 DELETING ALL STORED TRANSMITTER CODES 1 Turn the Power Off to the Drive Unit 2 Press and hold the blue Door Code button 9 Fig 21 on the Control panel 3 Turn the Power On again whi...

Page 16: ...o close time has been set If the P E path is not broken the door will remain open till the path is broken If the Door Opener in curs an obstruction not from the P E while closing the door will re open...

Page 17: ...OPENING FLASHING CLOSING FLASHING DOOR TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS ON AND OFF DOOR OBSTRUCTED WHEN CLOSING FLASHING BEEPS ON AND OFF DOOR OVERLOADED F...

Page 18: ...18 SPARE PARTS WHEN ORDERING SPARE PARTS QUOTE THE ORDER CODE NUM BER TO YOUR LOCAL IN...

Page 19: ...ion step 7 and 8 Lights malfunction or keep blowing Globe blown or incorrect globe Replace with 24V DC 15 watts Festoon globe Courtesy Light Flashing The Door Opener has detected a overload condition...

Page 20: ...ich arise out of a accidental damage to or normal wear and tear to the Product or to the Product s components b flood fire or lighting c incorrect improper or unreasonable maintenance and or use d ins...

Reviews: