![AUTOFLAME Mini Mk8 M.M. Installation And Commissioning Manual Download Page 62](http://html1.mh-extra.com/html/autoflame/mini-mk8-m-m/mini-mk8-m-m_installation-and-commissioning-manual_3021294062.webp)
62
3.4.6 Add Trim Data During Commissioning
在调试阶段添加
EGA
调节数据
If the option 12 is set to 2 or 3 during commissioning, then when setting the servomotors for the
HIGH, INTER, GOLDEN START, FGR START and START positions, the trim data will also need to be
saved for the fuel rich and air rich trim conditions. The message ‘Waiting for EGA readings’ will
display.
在选项
12
被设置为
2
或
3
的情况下,用户在进行伺服马达高火位,中间位,黄金启动位,烟气再
循环位和启动位的设置时还要设置富油和富气条件下的
EGA
调节数据。屏幕这时将显示“等待
E.G.A.
读数
”
。
Figure 3.4.6.i Sampling
取样
Press on the EGA tab to display the EGA readings.
按下
EGA
标签来显示
EGA
读数。