SMEV oVEn WITH GRILL InSTRUCTIonS
OF311FG & OF311FGT
The ovens, the cookers and the grill
compartment operate with the following gases
and corresponding supply pressures.
The category (or categories according to which
the appliance has been adjusted, is clearly
indicated on the packaging and on the data
plate attached to the back of the appliance.
Please check this data before connecting
appliance to gas cylinder.
The pressure regulator to be used between the
cylinder and the appliance must comply with
the categories indicated in the table below.
Category
mbar
Gas
Output of
the regulator
1 3 (50)
1 3 (50)
50
50
G 30
(Butane)
G 31
(Propane)
1.5 kg/h
1.5kg/h
1 3+
(28-30/37)
1 3 (30)
1 3+
(28-30/37)
1 3 (30)
28-30
30
37
30
G 30
(Butane)
G 31
(Propane)
1.5 kg/h
1.5kg/h
ATTEnTIon: the appliance must be
installed by specialist technicians in
accordance with current standards.
If operating problems should arise when the
appliance has been installed, it is advisable to
contact the retailer.
IMPoRTAnT: in order to avoid every
possible accident, it is essential for the
appliance to be installed according to
the descriptions contained in these
instructions. An incorrect installation
causes the loss of the guarantee.
Any modification of the appliance can
be dangerous.
GAS CYLInDER
The appliance must be connected to a gas
cylinder that operates at the same working
pressure that the appliance is designed. Check
the data plate affixed to the appliance.
The use of a type of gas and/or of a
pressure different from those prescribed
by SMEV, can cause irregular operating
conditions of the appliance; for this
reason, SMEV declines any responsibility
originating from incorrect use of the
appliance itself.
observe the following instructions
The gas cylinders must be pieced in the
comportment assigned to this purpose in a
vertical position with the valves and pressure
reducers fitted; the access to the same must
not be obstructed. It must be possible to
replace the cylinders easily and without
obstacles. After use, shut off gas supply from
the cylinder
When replacing the gas cylinder, the
following precautions shall be taken
1. Close taps of the appliance (pos. O);
2. Make sure there are no flames or fires lit in
the proximity;
3. Close valve of cylinder to be replaced;
4. Screw off regulator of empty cylinder, take
it out of the compartment assigned for
this purpose. For replacement carry out
operations using the reverse sequence.
Check possible gas leaks by means of a
soapy solution as described above.
smev oven
5. Ignite burners and check correct operation
of the same; in case of negative result,
contact an authorised technician
VISUAL fLAME ConTRoL
1. The flame is right, when its internal tongue
is blue and its outline well-defined.
2. If the flames have yellow tips and little
pressure, consult your dealer.
ELECTRICITY SUPPLY
The electricity supply is 12 Volts direct current
(D.C.).
Use the appliance only in a well
ventilated space
The ventilation openings must remain open
when the appliance are operating.
IGnITIon of THE APPLIAnCE
Manual Ignition: oven - Grill
1. Push in control knob slightly, turn to ignition
position. Light burner with match or lighter
keeping knob pushed in for 5-10 seconds.
2. Release knob and turn it to
required position.
Automatic Ignition: oven - Grill
1. For igniting oven or grill, open oven
door completely.
2. Push in control knob slightly, turn to
ignition position keeping it pushed in for
5-10 seconds.
3. Release knob and turn to
required position.
note:
Oven and grill burners will not light if
the door is not completely open.
Ignition of appliance with thermostat
Proceed as above, with or without electronic
ignition. The ignition position is obtained by
turning the control knob to a position between
1 and 6 for the oven and grill position (see
symbol
▲▲▲▲
)
For ovens with the thermostat, the different
positions of the knob correspond to the
following temperatures in ºC of the oven:
Position.
1
2
3
4
5
6
Temperature. 130 160 180 200 220 240
Important:
If ignition is unsuccessful, repeat
operation from the beginning; if necessary
have the appliance checked for a gas and/or
electricity failure in the appliance. If appliance
absolutely does not work, close gas tap inlet
and contact retailer. Before using oven for the
first time, let it run at maximum temperature
for the duration of ½ hour, without
foodstuffs inside.
Use oven gloves when handling hot elements.
In the event of the burner flames being
accidentally extinguished, turn off the burner
control and do not attempt to re-ignite the
burner for at least 1 minute.
This appliance is designed to cook foods
only. Any other use is considered incorrect
and dangerous. The manufacturer is not
responsible for any damage to persons or
parts due to incorrect installation, improper,
incorrect, or irresponsible use.
This appliance must be installed in
accordance with regulations in force and
only used in a well-ventilated space. Read
the instructions before installing or using
this appliance. The appliance must be
installed by specialist technicians.
SMEV hotplate units operate with the
following gases and corresponding supply
pressures. The category (or categories)
according to which the appliance has been
adjusted is clearly indicated on the packaging
and on the data plate attached to the back
of the appliance. Check this data before
connecting the appliance to the gas cylinder.
The pressure regulator to be used between the
cylinder and the appliance must comply with
the categories indicated in the table below.
Category
mbar
Gas
Output
13B/
P(30)
30
Butane
1.5kg/h
30
Propane
This appliance is not connected to a flue
terminal for discharging the product of
combustion to the outside.