equipment det
ails
82
equipment det
ails
83
5. During the initial operation of a brand new
appliance, a certain amount of fumes and
a slight smell may be noticed for a short
while. Remedial action is to immediately
run the heater at maximum output and to
ensure adequate room ventilation.
6. In winter, before switching on the heater,
remove all snow from the cowl.
7. Inspect the exhaust duct and all connections
at regular intervals and always whenever
there is a blowback (misfire). It is essential
that the exhaust duct is installed so that it
slopes upwards over its whole length and
is securely fixed with several clamps. Never
place any object on the exhaust duct, since
this could result in damage. The exhaust
duct connection to both the heater and the
cowl must be firm and well sealed. Do not
operate heaters with incorrectly fitted or
damaged exhaust ducts.
8. Never allow the warm air outlet on the
heater to be obstructed in any way. For
instance never hang washing on or in front
of the heater to dry. Misusing your heater
in this way could cause serious damage
from overheating. Do not place flammable
objects near the heater. Please follow these
guidelines in the interest of your own safety.
9. If the burner makes an unusual noise or
if the flame lifts off while burning, it is
likely that the regulator is faulty and it is
essential to have it checked.
10. Cleaning (with switched off appliance):
It is recommended that at least once a
year, before the heating season starts, you
remove any dust that has collected on the
heat exchanger base plate.
WARnInG: Surfaces become hot in
use, guards provided do not give full
protection to the young or elderly.
TECHnICAL DATA:
Type of gas:
Liquid gas (propane/butane)
operating pressure:
30mbar
Rated thermal output:
3400W
Gas consumption:
30-280 g/h
operating voltage:
1.5V
Power consumption:
50 MA (ignition)
0.01 MA (monitoring)
Product Indent. no:
CE-0085AP0325
CHAnGInG of BATTERIES
Changing the Batteries on the
Automatic Ignitor
Only change the batteries with the heater
switched off.
Always insert new batteries at the beginning of
the heating season.
Remove front of heater retaining screw,
located through centre of black grill. Unclip
front of heater, slide up battery cover to
reveal battery. Change the batteries. Observe
plus/minus.
Only use temperature resistant (+70°C), leak-
proof Mignon round cells (LR 6, AA, AM 3, Art.
no. 30010-23600). Other batteries could lead
to malfunctions!
TRUMA ULTRAHEAT ADDITIonAL ELECTRIC
HEATInG foR TRUMATIC S 3002
function description
Truma-Ultraheat is an additional 230V electric
heater for the LPG heater models Trumatic S
3002/S 5002.
Heater operation is basically possible with gas
only, electricity only or simultaneously with
electricity and gas.
When using simultaneously the electrical unit
will switch itself off before overheating occurs
as a result of the stronger gas burner.
When using electricity only we recommend to
set the fan control on position 3 (manual or
auto), remembering to set the output level to
2000W (ensure that the fuse protection for the
power supply of the camp site is sufficient).
If more than 2000W are required (heating up/
cold temperatures) you must refer back using
gas operations as the 230V electrical operation
is a secondary heater only.
The electric heater can also be operated
without the Trumavent fans.
WARnInG: Due to the design, the heater
front case will become hot during
operation. The operator is obliged to
ensure that due care is taken to protect
third parties (small children in particular).
oPERATInG InSTRUCTIonS
Before operating the heater for the first
time it is essential to observe the operating
instructions, enclosed with the heater.
Control panel with thermostat
a Rotary switch ‘Off’
b Rotary switch ‘On’
power settings:
500 - 1000 - 2000 W
c Rotary control knob for room
temperature (illuminated by green
indicator lamp ‘operation’)
Switching on
Attention: Before switching on, ensure that
the fuse protection for the power supply of
the campsite is sufficient for the selected
power setting (b) (see Technical Data).
Important: The electric feed line for the
caravan must be fully unwound from the
cable drum.
1. Switch the electric supply on at the fuse
spur marked Water Heater, normally in the
wardrobe.
2. To switch on, turn the rotary switch to the
desired output level (b).
3. Set rotary control knob (c) to the desired
room temperature.
The thermostat setting on the operating
element (1-9) must be determined individually
depending on the heating requirement and
the type of vehicle. For an average room
temperature of about 23°C, we recommend a
thermostat setting of about 6 -8.
Switching off
Switch the heating system off at the rotary
switch (a).
Important operating notes
1. Repairs may only be carried out by
an expert.
2. The heater’s hot air outlet should under
no circumstances be blocked. Never hang
clothes or similar in front of or on top
of the heater to dry. This could cause
serious damage to the heater as a result
of overheating. Do not place inflammable
materials near the heater! Please observe
these instructions for your own safety.
3. The performance of the room thermostat
will be affected if temporarily covered
or obstructed.
truma ultraheat