4. When operating a brand-new heater for
the first time (or after it has been idle for
a lengthy period) you may temporarily
notice a slight smoke and smell. We advise
running the heater at full power and
thoroughly ventilating the room.
5. Any modifications to the appliance or
the use of spare parts and accessories
important for operation which are not
original Truma parts, or non-observance of
the instructions for installation and use will
result in the guarantee becoming invalid
and no liability will be assumed.
Furthermore the approval for operating the
appliance will become invalid and in some
countries also the approval for operating
the vehicle.
TECHnICAL DATA
Power supply:
230 V ~, 50 Hz
Power consumption at power setting:
500 W: 2.2 A
1000 W: 4.5 A
2000 W: 8.5 A
Weight:
approx 2kg
The mains element on the space heater is
designed for supplementary heating. It is not
recommended to run alongside the gas for
prolonged periods of time.
TEB fAn
Always observe the operating instructions prior
to starting!
The vehicle owner is responsible for the correct
operation of the appliance.
Repairs are only to be carried out by an expert!
a Manual control
(e.g. for ventilation) Adjust desired output
at the control knob.
b Off
(or automatic operation/ heating with
heaters Trumatic S 3002 K and S 5002 K)
c Automatic operation
(Heating) The output steadily adjusts to
the respective heat emission of the heater.
The maximum output can be limited at the
control knob, as required. The regulating
between this value and slow running is
carried out automatically.
The quantity of air can be individually adjusted
at the air flap (f), for warm air distribution.
In centre position 50% of the warm air is
distributed to each outlet.
Use the fan duct with 72 mm and if the fan
ducts are of different lengths or on sides with a
greater heat requirement. This means that the
air output can be used to the full on this side.
By adjusting the air flap (f) the quantity of air
can be increased individually. This means that
the air out-put on the other side is reduced.
If the air output drops or the operating noise
increases, the fan impeller wheel may be
severely soiled.
a
b
c
f
Cleaning
(with switched off appliance!) We recommend
removing dust which has collected on the heat
exchanger and base plate of the heater and on
the impeller wheel of the Trumavent fan, once
a year before the heating season starts. Clean
the impeller wheel carefully using a brush or
tooth brush.
Blown air ducts
The air ducting outlets are generally of the
butterfly type and may be opened or closed
to control the quantity of air by adjusting the
butterfly valves. Twisting the disc in its housing
directs the flow in the direction required.
For uniform distribution, outlets nearest the
heater should be closed more than those
further away.
One outlet on each leg of the air ducting
layout must be kept open at all times.
Under no circumstances should the air ducting
outlets be blocked.
Butterfly outlet