Digiplexer 246 v2.5.x User Manual – 11/2010
Page 6
Head Office : Parc d’activites Kennedy - 20, avenue Neil Armstrong – F-33700 Bordeaux-Merignac (France)
Tel +33 (0)5 57 928 928 – Fax +33 (0)5 57 928 929 –
–
www.audemat.com
7. The device should only be operated on a stable electrical network. If the electrical
network is not stable, a power conditioner, such as a UPS, must be used.
8. Any maintenance, adjustment or repair must be carried out by qualified staff.
¾
Caution: LITHIUM BATTERIES
If the battery is not correctly replaced, there will be a risk of explosion.
Only replace it with a battery of the same type. Contact Audemat before attempting to use
another type.
Do not throw away used batteries; send them back to us.
1.3.
Licenses and options
a) Software
options:
¾
Full RDS
:
Configure up to 10 DSN (on 2 in basic RDS),
Manage EON (up to 9 EON in addition to the main PSN per DSN),
Manage
SLC,
Configure
ODA.
¾
Audio Backup
: additional source (file or MP3 stream in Shoutcast format) that will
replace the analog or AES inputs in case they fail.
Note: sampling frequency for audio files must be 48 kHz
¾
Advanced Audio Backup
: creation and management of embedded playlists that will
replace the analog or AES inputs in case they fail.
¾
MasterView
: with this application, visualize and control your site in custom views.
¾
1 to 2-band upgrade
.
¾
2 to 4-band upgrade
.
Please see Appendix A of this manual for upgrading procedures.
b) Hardware
options:
¾
Input / Output modules:
•
Digital inputs
: this module provides 16 digital inputs on a female SUB-D 25.
•
Relay outputs
: this module provides 8 relay closures on a male SUB-D 25.
•
Analog inputs
:
this module provides 8 analog inputs on a female SUB-D 25.
Five slots are available on the Digiplexer 246, to set up to 4 digital input modules, up to 5
relay output modules and up to 1 analog input module.
¾
Redundant power supply
: in case one power supply fails, the other one takes over, thus
allowing the unit to operate with no interruption. Also includes a UPS (Uninterruptible
Power Supply) to make it possible to send an alarm in case of complete power failure.
¾
FM Mod 0.5, 20 or 100W amplifier
: transmission and amplification module that
turns the unit into a transmitter.
Please see Appendix B of this manual for input / output configuration.