CHAPTER 7: MUX TAB - CONFIGURATION
MDU Solutions
®
– DVIS/DVISm - Digital Video Insertion System & Mini Digital Video Insertion System - Installation & Operation Manual
7-1
MUX
7. Mux Tab - Configuration
In this chapter we detail the multiplexer controls for the specific installation environment. All settings are discussed along with
limits and some suggestions as to what values are most applicable and why. If there is a Gigabit Ethernet output card installed,
this is the page where the Ethernet output is enabled. The Ethernet and RF outputs may be flexibly set to either RF, Ethernet,
or both simultaneous output types. While the Ethernet output is enabled here, it is not configured on this page. See
Tab - Configuration” on page 12-1
for Ethernet configuration.
FYI: In this guide, reference to DVIS infers DVIS and DVISm unless the model is specifically
stated.
7.1 Chapter Contents
•
•
•
•
7.2 Mux Settings
7.2.1 Transport Stream ID: [1-65535]
A Transport Stream ID is a unique number describing the transport stream. The default
value is 1 and supported values are 1 - 65535.
7.2.2 Service Provider Name:
An optional entry used to identify the provider of the service. This may or may not be supported or displayed by the end
customer decoder device.
7.2.3 Output Selection:
This check box selects which outputs are active. Ethernet may not be activated if there is no Ethernet output card installed in
Figure 7-1:
Mux Configuration Tab
Figure 7-2:
MUX Settings