GX 2 up to GX 5
Step
Action
1
Run the compressor until warm. Stop the compressor, close the air outlet valve and switch
off the voltage.
2
Remove the front and top panels.
3
Depressurise the compressor by unscrewing filler plug (8) one turn to permit any pressure
in the system to escape.
4
Depressurise the air receiver by opening drain valve (4).
5
Drain the oil by opening drain valve (5). Close the valve after draining. Deliver the spent
oil to the local oil collection service.
6
Remove oil filter (3) and separator (2). Clean the seats on the manifold.
7
Oil the gaskets of the new filter and separator and screw them into place. Tighten firmly
by hand.
8
Remove filler plug (8) and fill oil tank (7) with oil until the level reaches the middle of sight-
glass (6). Ensure no dirt gets into the system. Refit and tighten filler plug (8).
9
Unscrew the air filter cover (1), remove the filter element and carefully pour approx. 0.1 l
(0.03 US gal / 0.02 Imp gal) of oil into the compressor element. Do not overfill.
10
Re-assemble the inlet filter
11
Fit the bodywork panels.
12
Close drain valve (4) of the air receiver.
13
Run the compressor for a few minutes. Check the oil level.
Instruction book
2920 7105 31
51
Summary of Contents for GX 2 EP
Page 2: ......
Page 13: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7105 31 11 ...
Page 16: ...2 3 Oil system GX Pack Instruction book 14 2920 7105 31 ...
Page 18: ...2 4 Cooling system Pack units Instruction book 16 2920 7105 31 ...
Page 27: ...GX 7 EP IEC units with Y D start Instruction book 2920 7105 31 25 ...
Page 28: ...GX 7 EP for 208 230 460V 60 Hz DOL Instruction book 26 2920 7105 31 ...
Page 37: ...GX 7 EP Pack on 200l receiver 2 Cooling air inlet Instruction book 2920 7105 31 35 ...
Page 74: ......
Page 75: ......