Oil filler plug
This procedure should be carried out at the end of the compressor’s service life.
Step
Action
1
Stop the compressor and close the air outlet valve (2).
2
Switch off the voltage and disconnect the compressor from the mains.
3
Depressurise the compressor by opening plug (3) one turn.
Open condensate drain valve (4) of the air receiver.
4
Shut off and depressurise the part of the air net which is connected to the outlet valve.
Disconnect the compressor from the air net.
5
Drain the oil and condensate circuits.
6
Disconnect the compressor condensate outlet and valve from the condensate net.
Instruction book
2920 7105 31
47