Starting the compressor
Step
Action
1
Check the oil level sight glass (SG). The oil level should be in the middle. If it is below the
minimum level, top up to the middle. Do not overfill.
2
Switch on the voltage by turning switch (1) to position I
3
Open air outlet valve (2).
4
Start the unit by moving selector switch (S) to position I
5
Regularly check the working pressure (Gpa).
6
On Full-Feature compressors, regularly check that condensate is drained during operation.
4.3
Stopping
Air outlet valve
Instruction book
44
2920 7105 31