Frequency
(Hz)
Voltage (V) Overload
relay (OL),
GX 7 (A)
Main fuses,
compressor
supply, GX 7 (A)
Main fuses, dryer
supply (A)
cULus
DOL
Type J or
RK
Type
CC
Type J or
RK
Type
CC
60
200-208
36.3
50
-
4.5
8
60
230
34.4
45
-
4.5
8
60
460
16.9
25
25
4.5
8
60
575
13.8
20
15
4.5
8
(1): Motor circuit breaker with residual current device type D
8.4
Reference conditions and limitations
Reference conditions
Air inlet pressure (absolute)
bar
1
Air inlet pressure (absolute)
psi
14.5
Air inlet temperature
˚C
20
Air inlet temperature
˚F
68
Relative humidity
%
0
Working pressure
bar(e)
See
Compressor data
Working pressure
psi
See
Compressor data
Limitations
Maximum working pressure
bar(e)
See
Compressor data
Maximum working pressure
psig
See
Compressor data
Minimum working pressure
bar(e)
4
Minimum working pressure
psig
58
Maximum air inlet temperature
˚C
46
Maximum air inlet temperature
˚F
115
Minimum ambient temperature
˚C
0
Minimum ambient temperature
˚F
32
8.5
Compressor data
All data specified below apply under reference conditions, see section Reference
conditions and limitations..
Instruction book
2920 7105 31
63
Summary of Contents for GX 2 EP
Page 2: ......
Page 13: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7105 31 11 ...
Page 16: ...2 3 Oil system GX Pack Instruction book 14 2920 7105 31 ...
Page 18: ...2 4 Cooling system Pack units Instruction book 16 2920 7105 31 ...
Page 27: ...GX 7 EP IEC units with Y D start Instruction book 2920 7105 31 25 ...
Page 28: ...GX 7 EP for 208 230 460V 60 Hz DOL Instruction book 26 2920 7105 31 ...
Page 37: ...GX 7 EP Pack on 200l receiver 2 Cooling air inlet Instruction book 2920 7105 31 35 ...
Page 74: ......
Page 75: ......