GX Full-Feature
Air pressure in the oil separator tank (OT) forces the oil from the tank to compressor element (E) via oil cooler
(Co) and oil filter (OF). Compressed air and oil flow into oil separator/tank (OT) where most of the oil is
separated from the air by centrifugal action. The remaining oil is removed by oil separator (OS) and returns
to the oil circuit via a separate line. The minimum pressure valve (Vp - see section
Air flow
) ensures a minimal
pressure in the tank, required for oil circulation under all circumstances.
The oil circuit has a thermostatic bypass valve (BV). The oil cooler is bypassed until the oil is warm.