Attention
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised
parts is not covered by Warranty or Product Liability.
Apply all relevant
Safety precautions during maintenance or repair
.
GX 2 EP to GX 5 EP:
•
Move start/stop switch (S) to position 0.
•
Turn off main switch (1)
GX 7 EP:
•
Move selector switch (S) to unload position.
•
Wait at least 30 seconds and turn off mains switch (1)
Move dryer on/off switch (6) to position 0.
Wait until the compressor has stopped and switch off the voltage. See the
Stopping
section.
Open the isolating switch to prevent an accidental start.
Close air outlet valve (2) and depressurise the compressor by opening the oil filler plug (3)
one turn.
Open manual condensate drain valves (4 and/or 5).
The air outlet valve (2) can be locked during maintenance or repair as follows:
•
Close the valve.
•
Remove the screw fixing the handle
•
Lift the handle and turn it until the slot of the handle fits over the blocking edge on the
valve body.
•
Fit the screw.
Faults and remedies
For all references given hereafter, see
Air flow diagram
,
Initial start-up
or
Regulating system
.
Compressor
Condition
Fault
Remedy
1
The machine does not start
No power
Check power supply
Fuse (F1) blown
Replace fuse
The main motor thermal
protection has tripped
Check and let motor cool down; to
reset/restart, move compressor start/
stop switch to 0, then to I
2
The machine does not start,
high oil temperature lamp is on
(temperature switch tripped)
Oil cooler is dirty
Clean cooler
Ambient temperature too high Improve ventilation in compressor
room
Oil level too low
Top up oil tank
3
The compressor does not
reach working pressure
Blow-off solenoid valve (Y1)
remains open
Check; replace valve if necessary
4
Excess oil consumption
Oil separator (OS) clogged
Replace oil separator
Oil level too high
Drain to correct level
Air dryer
Condition
Fault
Remedy
1
No compressed air passes
through the dryer
Pipes are frozen inside
Hot-gas by-pass valve
malfunctioning; consult Atlas Copco
Instruction book
58
2920 7105 31
Summary of Contents for GX 2 EP
Page 2: ......
Page 13: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7105 31 11 ...
Page 16: ...2 3 Oil system GX Pack Instruction book 14 2920 7105 31 ...
Page 18: ...2 4 Cooling system Pack units Instruction book 16 2920 7105 31 ...
Page 27: ...GX 7 EP IEC units with Y D start Instruction book 2920 7105 31 25 ...
Page 28: ...GX 7 EP for 208 230 460V 60 Hz DOL Instruction book 26 2920 7105 31 ...
Page 37: ...GX 7 EP Pack on 200l receiver 2 Cooling air inlet Instruction book 2920 7105 31 35 ...
Page 74: ......
Page 75: ......