Voisus-VBS2 Plugin Troubleshooting Procedures
If you are experiencing issues relating to the Voisus-VBS2 plugin, perform the following proce-
dures to determine the source of the problem and find a remedy.
A. General Voisus-VBS2 Plugin Troubleshooting
1. If the Voisus-VBS2 GUI reports “No Response from Server”, check your mission init.sqf
file and make sure that the listed ‘Server_IP’ matches the network configuration for your
Target.
2. When upgrading or re-installing VBS2, you will need to un-install and reinstall the Voi-
sus-VBS2 Plugin. To un-install the Voisus BS2 plugin:
a. Deactivate all of the missions and installations via Voisus VBS2 Manager.
b. Hand edit the init.sqf files to remove the code between
/**** START ASTi VBS2 GUI CODE ****/
and
/**** END ASTi VBS2 GUI CODE ****/
c. Use the Windows control panel Program and Features (for Windows Vista and 7) or
Add Remove Programs (for Windows XP) to remove the Voisus VBS2 Manager.
3. The Voisus-VBS2 Plugin installer includes four important elements that are required for
proper functionality.
a. Voisus VBS2 Manager
b.
[VBS2 install directory]
\ plugins \ ASTiVoisus.dll
c.
[VBS2 install directory]
\
My Content \ Add ons \ astivoisus.pbo
d. C:\Documents and Settings \ <username> \ Voisus \ VBS2 init. file