26 -
Model 12-1015 Users’ Manual Version 13.08
Associated Equipment Corp.
5043 Farlin Ave.
800-949-1472(US)
St. Louis, MO 63115
314-385-5178 (Outside US)
analyzer. To perform the test, just clamp the analyzer clips onto the battery
terminals and it will display the screen (Fig.31) as shown if its voltage falls
below the normal 12.0 volts.
Press key to continue and the display will show: (Fig.32)
Check the battery ratings and enter it as described in steps 10 to 12 (page
19~21) and the results will show as an example below: (Fig. 33 and Fig.34)
Figure 31
Figure 32
Figure 33
Battery voltage is
below 12.00 Volts!
Press [Enter] to
continue...
Select
Rating
CCA
SAE
DIN
JIS
IEC
EN
CA
Battery: OK-Recharge
Measured: 220 CCA
Rating: 400 CCA
Volts: 11.96 V
Int. R: 12.24 mOhm
State of Charge is
low! Charge battery
and test again.
Battery: To replace
Measured: 120 CCA
Rating: 400 CCA
Volts: 10.56 V
Int. R: 20.24 mOhm
State of Charge is
low! Internal
resistance is high.
Figure 34