21 -
Model 12-1015 Users’ Manual Version 13.08
Associated Equipment Corp.
5043 Farlin Ave.
800-949-1472(US)
St. Louis, MO 63115
314-385-5178 (Outside US)
Press key and the display will show: (Fig.26) below:
12. Referring to the Table list (Fig.25) basing on 80D26L, check the battery
type: WET, MF, Sealed MF or Closed MF (CMF) as each category has
different CCA ratings. For instance, if the battery is a Sealed MF (CMF)
then it is rated at 630 CCA.
Note:
WET -
Wet Cell Type
MF
-
Maintenance Free Type
SMF -
Closed or Sealed Maintenance Free
13. To enter the value 630, press key will increase the original value
of 500 (Fig.26) by step of 100 units to 600. Likewise use key to
increase the last two digits (00) to 30 by step of 5 units for each pressing.
(Fig. 27)
Figure 26
Figure 27
Input Battery Rating
Increase/decrease:
Single digit
⊳
By hundredth
500 CCA
Press [Enter] to
proceed.
Input Battery Rating
Increase/decrease:
Single digit
⊳
By hundredths
630 CCA
Press [Enter] to
proceed.