43 -
Model 12-1015 Users’ Manual Version 13.08
Associated Equipment Corp.
5043 Farlin Ave.
800-949-1472(US)
St. Louis, MO 63115
314-385-5178 (Outside US)
No Load Test
At 3,000 rpm:
Av Volts: 14.2V
<15.0V: Max. 14.6V
>13.3V: Min. 13.8V
Press [Enter] for
results.
Start the engine and then press key again and the screen will
prompt you as shown below (Fig. 59).
Follow the instructions, make sure that all loads (lights, air-condition, etc)
are OFF. Rev the engine up to 3,000 ~ 3,500 RPM by referring to the
dashboard meter, then press key and maintain the engine speed for
about 10 seconds and release the pedal. The maximum and minimum
voltages values will be captured.
After that press key again and it show as below (Fig 60.)
With the captured readings, analysis can done by referring to the limits as
indicated that MAX voltage should not exceed 15.0V (max. voltage at
3,000 RPM) and MIN voltage should be more than 13.3V (min voltage
during idling speed).
Figure 60
Figure 59
Average
Charging Volts
Charging Volts
range limit.
Captured Volts
readings
No Load Test
Make sure all
electrical loads are
turn OFF. Rev the
engine to 3,000 rpm.
Press [Enter].Hold
on to this 3,000 rpm
for 10 seconds and
release the pedal.