EFD1000 E5 Dual Electronic Flight Instrument (EFI) Install Manual
DOCUMENT # 900-00041-001
PAGE 23-226
REVISION D
© Copyright 2019 Aspen Avionics Inc.
2
Equipment Specifications and Limitations
2.1
EFD1000 E5
2.1.1
General Specifications
Part Number ...................... 910-00101-001
Width/Height ..................... 3.50 in./7.00 in. (Measured at Bezel)
Can Depth ......................... 4.15 in. (Rear of Bezel to Rear of Can)
Overall Depth .................... 6.35 in. (Knob to Rear Pressure Fitting)
Weight ............................... 2.9 lbs. with bracket
Display Type ...................... 6.0 in. Diagonal LCD (400x760)
Face .................................. Anti-Reflective Coated Glass
Backlight ........................... High Intensity White LED
Rotary Knobs ..................... Optical Encoder with Momentary Push
Dimming ........................... Manual & Automatic (Front Bezel Mounted Sensor)
2.1.2
Operational Specifications
Operating Temp ................ -20°C to +70°C
Storage Temp .................... -55°C to +85°C
Max Operating Altitude ..... 35,000 ft. Unpressurized/ 55,000 ft. Pressurized
Cooling ............................. Integral Fan
Max Humidity .................... 95% at 50°C
Input Voltage ..................... +9 to +32 VDC (Note: Input power must transition >11VDC
to turn on the unit
Nominal Current ................ 2.4/4.8 Amps (28v/14v)
2.1.3
I/O Specifications
ARINC 429 Inputs .............. 2 Low/High Speed
ARINC 429 Outputs ........... 1 Low/High Speed
RS-232 Inputs ................... 2
RS-232 Outputs ................ 3
Pitot/Static ........................ Quick Connect
2.1.4
Certification Specifications
FAA-PMA