AIP 6350 / Office 35IP
38
Expansion Card AIP 6350
5. Use AIMS to allocate the call numbers of the IP terminals to the new port
numbers (CM_1_1_3_Subscriber) so the subscriber data can be re-assigned.
6. Check the configuration using AIMS and unlock the card (CM_1_4_5_AIP
Cards, Setting "AIP Card On/Off").
7. Carry out a functional check.
5.7.4 Retrofitting an AIP card with DRS modules.
An AIP card can also be retrofitted with DRS modules:
1. Disconnect the PBX from the power supply.
2. Remove the AIP card as indicated in the Ascotel IntelliGate System Manual.
3. Fit the DRS modules.
4. Reinsert the AIP card as indicated in the Chapter "Fitting and Removing an
AIP Card", page 36 and switch the PBX back on.
The DRS module is automatically detected by the system.
5.7.5 Initialization and Restart of the AIP Card
When the PBX is first initialised the AIP configuration data is also reset to its ini-
tialisation values. The IP addresses of the AIP card and the IP terminals are not
reset.
During a PBX restart the AIP card is also re-initialized. The configuration data is
retained.
A restart of the AIP card on its own can be obtained using AIMS (CM_1_4_5_AIP
Cards).