3.
The next test is for the pull force. If the pull force is above the minimum setting this screen will fade
away and step 4 will appear. If not make necessary adjustments and repeat this step.
4.
If the programmed wire has a terminal on both ends steps 2 and 3 will repeat.
5. The next wire will be a complete assembly for inspection. After the operator clicks the green check in the
window, the machine will say “Qualification complete”
6. The programmed quantities will now appear.
Bar code scanning
Part Selection
The bar code scanner should be configured so that it outputs data in USB keyboard format and has a CR suffix.
This means you can scan information into any data field that accepts keyboard entry. For companies that name
the parts the same in both the Artos software and on their work orders, a bar code scanner can be used to select
the part. This is especially useful when you have large number of parts programmed in the Artos software.
Using the scanner to select an item in a drop down menu.
1. Use your mouse to click in the drop down field. The field will be highlighted in blue.
2. Scan the bar code on your work order your work order.
Material Validation
When the machine is set for material validation mode, you have to scan the bar code of the wire, terminals, and
applicators before you are allowed to run. It should be noted here that the bar code scanner should be configured
so that it outputs data in USB keyboard format and has a CR suffix. This means you can scan information into
any data field that accepts keyboard entry.
Field for part
selection