100
Complete part
is the check of the completed part as a unit after all the individual quality checks has been
done.
Wire length test
will give you a measured and stripped wire so you can inspect the overall length and the
strip length and quality.
Process check
will allow the inspection of the end processes such as crimping and tinning.
Qualify batch job
will run the qualification process between parts in a batch type
JOB
program.
Pull Force test
will allow pull testing of the crimp to a value pre-set in the process set-up by means of an
integrated pull tester. If the test passes the machine will move on to the next step in the process.
Crimping height test
will allow measurement of the crimp to a value pre-set in the process set-up by
means of an integrated micrometer. If the test passes the machine will move on to the next step in the
process.
Requalify after crimp height change only
checking this will allow you to make changes to the lead and
tail process settings and the lead and tail crimp settings. Only changing the crimp height in the lead or tail
crimp settings window will force the user to do a new qualification.
Requalify after any crimp setting or processing setting changes
(default specification) any changes
in the lead and tail process settings or lead and tail crimp settings will force the user to do a new
qualification.
Learn CFM (Short length)
The machine will automatically start the CFM learn process for each end of
the wire that has a terminal and has CFM enabled. The length of the wire for these parts will be 100mm.
These parts will not be counted as part of the production batch.
Learn CFM (Standard length)
The machine will automatically start the CFM learn process for each end
of the wire that has a terminal and has CFM enabled. The part length will be the length programmed on
the run screen. These parts will be counted as part of the production batch.
Integrated Testing Equipment
Your machine can be equipped with integrated micrometer and pull tester. When these are installed they must be
selected in the “
Machine Configuration
” under the “
Crimper
” tab.