![Arris ICX 7650-48P Configuration Manual Download Page 102](http://html1.mh-extra.com/html/arris/icx-7650-48p/icx-7650-48p_configuration-manual_2976303102.webp)
The following example converts stacking port 1/3/3 to a data port.
ICX7150-24 Router# configure terminal
ICX7150-24 Router(config)# stack unit 1
ICX7150-24 Router(config-unit-1)# no stack-port 1/3/3
stack-port 1/3/3 is removed.
ICX7150-24 Router(config-unit-1)# show stack
T=41m15.7: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX7150-24 active 00e0.5200.0100 128 local Ready
2 S ICX7150-48P standby 748e.f882.e418 0 remote Ready
standby active
+---+ +---+
3/3| 2 |3/1==3/1| 1 |
+---+ +---+
Will assign standby in 58 sec due to all ready
Standby u2 - protocols ready, can failover
Current stack management MAC is 00e0.5200.0100
ICX 7250 stack configuration overview
The following table provides an overview of ICX 7250 stacking capabilities.
TABLE 21
ICX 7250 stacking capability
Stacking capability
ICX 7250
Additional information
Topologies supported
Ring and linear
Refer to
103.
Maximum stack size
12 units
Stacking and SPX configurations. Any
combination of ICX 7250 devices may be
stacked. When a stand-alone ICX 7250 is
configured as a PE unit attached to a control
bridge in an 802.1br SPX configuration,
scaling is increased. Refer to the Ruckus
FastIron Campus Fabric Configuration Guide for
more information.
Maximum stacking distance
10 Kilometers
Refer to
FastIron stacking distances and
on page 50 for more
information.
Stacking ports
Four 10-Gbps stacking ports (from eight
available ports) on fixed module on front
panel
Module 2 on the front panel contains four
stacking ports and four uplink ports, which
can be used as alternative ports for stacking.
Refer to
103 for module and port locations.
Valid-stack-port sets
Factory set (x/2/1, x/2/3, 2) or (x/2/5, x/2/7, 2)
NOTE
The third number in each set is
the maximum number of ports in
a stacking trunk.
Refer to the definition of valid-stack-port set
in
on page 19 and
on page 23 for more
information.
Refer to
103 for port locations.
Stacking by Device
ICX 7250 stack configuration overview
Ruckus FastIron Stacking Configuration Guide, 08.0.90
102
Part Number: 53-1005572-01
Summary of Contents for ICX 7650-48P
Page 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Page 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Page 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Page 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Page 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...