TABLE 24
ICX 7750 stacking capability (continued)
Stacking capability
ICX 7750
Additional information
Stacking ports
12 total ports available simultaneously:
Six 40-Gbps ports, Module 2: 1/2/1 to 1/2/6
(Front)
and
Six 40-Gbps ports, Module 3: 1/3/1 to 1/3/6
(Rear)
Refer to "Valid-stack-port sets" in this table
for information on using Module 2 (right
front) and Module 3 (rear) simultaneously for
stacking.
Valid-stack-port sets
There are 6 valid-stack-port sets:
(x/2/1, x/2/4, 3)
(x/3/1, x/3/4, 3)
(x/2/1, x/3/1, 6)
(x/2/5, x/2/6, 1)
(x/3/5, x/3/6, 1)
(x/2/5, x/3/5, 2)
NOTE
The third number in the set is the
maximum number of ports in a
stacking trunk. One indicates a
single stack-port only.
Refer to the definition of valid-stack-port set
in
on page 19 and
on page 23 for more
information.
Refer to
138 for port locations.
Reconfigurable ports
Use the stack-port and stack-trunk
commands to reconfigure ports.
Trunks
Up to two stack trunks
NOTE
Refer to
on page 147.
NOTE
To set up long-distance stacking
trunks on 48-port units, refer to
Installing the ICX 7750 in a remote
on page 143.
Refer to "Valid-stack-port sets" in this table
for common trunk configurations.
Linear-topology trunks
The following maximum linear-topology
trunks are supported:
1/2/1 to 1/2/6 and 1/3/1 to 1/3/6
or
1/2/5 to 1/2/6 and 1/3/5 to 1/3/6
Refer to
Support for two-unit stack linear-
on page 36 for more
information.
Hitless switchover and hitless failover
Supported
Refer to
on page 171.
License requirements
No license required for stack-port
configuration. No license required for
Premium features.
For more information on ICX 7750 license
options, refer to the Ruckus FastIron Software
Licensing Guide.
Configuration options
Manual and automatic, including stack
interactive-setup and zero-touch provisioning
Refer to
56.
Access methods
TFTP, SCP
Software images, boot images, and signatures
can be downloaded to a stack using TFTP and
SCP applications. Refer to the Ruckus FastIron
Software Upgrade Guide for more information.
Stacking by Device
ICX 7750 stack configuration overview
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
137
Summary of Contents for ICX 7650-48P
Page 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Page 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Page 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Page 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Page 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...