!!! Temperature is over warning level on stack unit 1 !!!
Detect stack unit 3 has different startup config flash, will synchronize it
Detect stack unit 3 has different ssh rsahost key, will synchronize it
T:3h49m7.9: Done hot swap: active controller u1 sets u3 to Ready.
T=3h49m7.9: Synchronize startup config to u3
Flash Memory Write (8192 bytes per dot)
.
Write startup-config done.
T=3h49m31.3: Election, was active, no change, ID=1, pri=128, 3U(1-3), A=u1, nbr#=1 1, reason: u2: port-up, ,
Stack unit 3 Power supply 1 is up
Stack unit 3 Power supply 2 is down
T=3h49m35.5: Election, was active, no change, ID=1, pri=128, 3U(1-3), A=u1, nbr#=2 2, reason: u3: port-up, ,
SSH RSA Host Key erase request sent to specified stack member(s)...
T=3h49m16.7: Synchronize ssh rsa host key to u3
ICX7750-26Q Router#
When the interactive-setup process is complete, output for the show stack command confirms that the configuration is the
same. The provisional configuration has been applied to the two replacement units, 2 and 3, and the state has changed to
"remote" for both units.
ICX7750-26Q Router# show stack
T=3h49m27.4: alone: standalone, D: dynamic cfg, S: static
ID Type Role Mac Address Pri State Comment
1 S ICX7750-20QXG active cc4e.2438.7280 128 local Ready
2 S ICX7750-48XGF member 609c.9f7f.9400 0 remote Ready
3 S ICX7750-20QXG member 748e.f8f9.6300 0 remote Ready
active
+---+ +---+ +---+
=2/1| 1 |2/4==2/1| 3 |2/4==2/4| 2 |2/1=
| +---+ +---+ +---+ |
| |
|-------------------------------------|
There is no standby. Will assign a standby in 47 sec
Current stack management MAC is cc4e.2438.7280
Moving a unit to another stack
Moving a member from one stack to another stack can cause non-sequential ID assignment. The active controller will honor the
original ID of the newly added unit if the ID is not already in use. The active controller assigns a new ID if the original ID is already
in use. You can user the stack interactive-setup command to change the ID of the new unit. Refer to
on page 75 for more information.
Removing an active controller from a powered stack
To remove an active controller from a powered stack, disconnect the active controller. The standby controller waits for 30
seconds and then assumes the role of active controller. If hitless failover is enabled on the stack, the standby controller takes
over immediately. A single active controller device functions as a standalone unit even if it is still stacking-enabled. You do not
have to issue a stack unconfigure me command for an active controller.
Reloading a stack unit
Use the reload command to reload one or more stack units, for example, when necessary to repair a malfunctioning unit. Stack
units can be reloaded only if they are not the active controller.
Stack Management
Reloading a stack unit
Ruckus FastIron Stacking Configuration Guide, 08.0.90
Part Number: 53-1005572-01
215
Summary of Contents for ICX 7650-48P
Page 8: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 8 Part Number 53 1005572 01...
Page 22: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 22 Part Number 53 1005572 01...
Page 88: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 88 Part Number 53 1005572 01...
Page 170: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 170 Part Number 53 1005572 01...
Page 236: ...Ruckus FastIron Stacking Configuration Guide 08 0 90 236 Part Number 53 1005572 01...