61
Camera Operation
Symbol
Meaning
glows
The display is in Mode 1.
bat
glows
Battery voltage too low for the set frame rate
≤
130 fps and voltage < 20.6 V
130 - 150 fps and voltage < 24V
blinks
Battery is too "soft", voltage will collapse on use
asy
glows
Asynchronous operation
(camera is not running at set frame rate)
blinks
Movement/shutter not synchronous
end
glows
film end
fps
blinks
The magazine is not suited to the set frame rate, or
ESU is connected
and no sync-frequency is available
PROG
glows
The stored program is activated and can be started while
the camera is running by depressing the "PROG"-button.
blinks
The activated program cannot be run with the set values:
e. g.: incorrect magazine for the frame rate set in the
program, or battery voltage too low for the frame rate set
in the program.
Symbol
Meaning
blinks
Only on ARRIFLEX 435ES:
The shutter is mechanically locked in electronic operation
or
the electronic shutter function is switched off.
The symbol blinks and the operation control indicator glows
red although the shutter is not locked:
The electronic shutter adjustment is defective –
the electronic shutter adjustment can be switched off
see chapter 5.
R
glows
Reverse operation is switched on.
TC
glows
TC-generator is switched on and set.
blinks
TC-generator is switched on
during running: no recording
during standby: the last synchronization was over 8 hours ago
additional acoustic warning,
see also TC warning display.
Overview of Display Symbols
Summary of Contents for ARRIFLEX 435 ES
Page 10: ...Introduction 10 magazine opening cover movement in locked position loop protector...
Page 16: ...Installation 16 shoulder set S 4 shoulder cushion base plate...
Page 24: ...Power Supply 24...
Page 48: ...Camera Body 48...
Page 56: ...Optics 56...
Page 74: ...Video Assist Saystem 74...
Page 98: ...Accessories 98...
Page 122: ...Maintenance 122...