7.13 The Outputs Screen
51
7.13.3
Seconds Per Pulse Mode
Choose this programmable pulse mode to provide a pulse every X number of seconds, where X can
be from 1 to 60,000 seconds. After configuring the pulse mode, make sure to change the jumper
for the chosen port to programmable pulse. See Table 5.1.
Figure 7.13: Programmable Pulse Seconds Per Pulse Screen
7.13.4
Pulse Per Hour Mode
Choose this programmable pulse mode to provide a pulse every X number of seconds after the hour,
where X can be from 0 to 3,599 seconds. Configure the pulse width, from 10 milliseconds to 600
seconds. After configuring the pulse mode, make sure to change the jumper for the chosen port to
programmable pulse. See Table 5.1.
Figure 7.14: Programmable Pulse, Pulse Per Hour Screen
Summary of Contents for 1201B
Page 4: ...iv ...
Page 153: ...B 7 Four Fiber Optic Outputs 135 Figure B 4 Jumper Locations ...