C.12 Option 28: Power System Time, Frequency and Phase Monitor
121
Return System Time
Command:
TS
TS returns the Option 28 system time.
Response:
MM DD YYYY hh:mm:ss.ssss SS
C
Where:
MM = Month
ss.ssss = seconds
DD = Day of Year
SS = UTC seconds
YYYY = Year
hh = hour
mm = minute
Set Option 28 System Time, UTC
Command:
SU
SU sets the Option 28 to reflect system time in UTC format.
Response:
C
Set Option 28 System Time, Local
Command:
SL
SL sets the Option 28 to reflect system time in UTC format.
Response:
C
Return System Status
Command:
SM
SM returns the Option 28 system status.
Response:
h
C
Where (h):
0 = System OK
1 = No System Reference
2 = System okay now but reference lost since last request
Start Broadcast Mode–Vorne
Command:
B2
B2 configures RS-232 broadcast mode to support Vorne large format time displays. Data is trans-
mitted ahead of time, and the
<
BEL
>
character is transmitted on time. When properly configured,
the Vorne display updates simultaneously upon receipt of the
<
BEL
>
character. Refer to Arbiter
Systems Application Note 103 for more information.
Response:
11nn
C
Out-Of-Lock Time
1/second
44hhmmss
C
UTC/Local Time
22
±
ff.fff
C
Frequency Deviation
33
±
s.ss
C
Time Deviation*
34
±
sss.sss
C
Time Deviation*
66hhmmss
C
System Time
Summary of Contents for 1092A
Page 4: ...iv ...
Page 18: ...xviii LIST OF TABLES ...
Page 129: ...C 10 Option 20A Four Fiber Optic Outputs 111 Figure C 7 Option 20A Jumper Locations ...
Page 131: ...C 11 Option 27 8 Channel High Drive 113 Figure C 8 Option 27 Jumper Locations ...
Page 148: ...130 Options List Figure C 10 Option 29 Connector Signal Locations ...