Automatic functions
par.
Fig. 97
From “Home” screen, press
.
15.3.1 Application rate regulation
Enables / disables automatic output adjustment
(DEFAULT: ON)
.
"HOME" SCREEN
Automatic adjustment ON
Automatic adjustment OFF
Fig. 98
15.3.2 Test speed
Allows enabling / disabling speed simulation (
DEFAULT: OFF
).
The simulation allows carrying out regulation tests with stopped machine (default presetting at 6 km/h - 3.7 MPh).
"HOME" SCREEN
Fig. 99
Simulation speed modification:
with active simulation press the indicated keys
Increase
Decrease
Quits without confirming the
changes
Saves the changes
Delete
Quit
Confirm
Goes back to previous menu,
or scrolls the pages of a menu
(previous page)
Scrolls the pages of a menu
(next page)
Goes back to Main screen
Saves the changes to current
page
AUTOMATIC ADJUSTMENT ON
The VT keeps the set application rate constant regardless of the changes in speed
and boom section status.
In this case the spray rate can be set with the proper functions
Manage presets
(
par.
) -
Change target rate
(
par.
or by uploading a prescription map from TC.
If necessary, during spraying, it is possible to operate the output control
(Auxiliary Input) to adjust output to crop conditions, increasing or decreasing
momentarily the application rate up to ±50%.
AUTOMATIC ADJUSTMENT OFF (MANUAL)
Rate manual regulation shall be carried out using the proper control (Auxiliary Input).